Human Angiogenesis Array G1000
Update:2014/7/20 20:30:16 View:2501
- Type AAH-ANG-G1000
- Description
Raybiotech Antibody Arrays
Introduction
Product Features
- High sensitivity and specificity
- Low sample volume (10-100 µl per array)
- Large dynamic range of detection
- Compatible with most sample types
- Test 4 or 8 samples on each slide
- Suitable for high-throughput assays
Target Names
Scroll over each target protein for more information |
||||
Angiogenin
|
Angiopoietin-1
|
Angiopoietin-2
|
Angiosestatin
|
bFGF
|
EGF
|
ENA-78
(CXCL5) |
Endostatin
|
GCSF
|
GM-CSF
|
GRO alpha/beta/gamma
|
I-309
(TCA-3/CCL1) |
IFN-gamma
|
IGF-1
|
IL-10
|
IL-1 alpha
(IL-1 F1) |
IL-1 beta
(IL-1 F2) |
IL-2
|
IL-4
|
IL-6
|
IL-8
(CXCL8) |
I-TAC
(CXCL11) |
Leptin
|
MCP-1
(CCL2) |
MCP-3
(MARC/CCL7) |
MCP-4
(CCL13) |
MMP-1
|
MMP-9
|
PDGF-BB
|
PECAM-1
(CD31) |
PLGF
|
RANTES
(CCL5) |
TGF beta 1
|
Thrombopoietin
(TPO) |
Tie-2
|
TIMP-1
|
TIMP-2
|
TNF alpha
|
uPAR
|
VEGF-A
|
VEGFR2
|
VEGFR3
|
VEGF-D
|
Species Detected
Human
Application Notes
Suggested Application
Multiplexed Protein Detection; Detection of Relative Protein Expression; Detecting Patterns of Cytokine Expression; Biomarker Screening; Identifying Key Factors; Confirming a Biological Process
Kit Components
- Human Angiogenesis Antibody Array G1000 Slide(s)
- Blocking Buffer
- Wash Buffer 1
- Wash Buffer 2
- Biotinylated Detection Antibody Cocktail
- Streptavidin-Conjugated Fluor
- Lysis Buffer
- Adhesive Plastic Strips
- 30 ml Centrifuge Tube
- Manual
Other Materials Required
- Small plastic boxes or containers
- Pipettors, pipette tips and other common lab consumables
- Orbital shaker or oscillating rocker
- Aluminum foil
- Gene microarray scanner or similar laser fluorescence scanner
Protocol Outline
- Dry the glass slide
- Block array surface
- Incubate with Sample
- Incubate with Biotinylated Detection Antibody Cocktail
- Incubate with Streptavidin-Conjugated Fluor
- Disassemble the glass slide
- Scan with a gene microarray laser scanner
- Perform densitometry and analysis
Storage/Stability
For best results, store the entire kit frozen at -20°C upon arrival. Stored frozen, the kit will be stable for at least 6 months which is the duration of the product warranty period. Once thawed, store array slide(s) and 1X Blocking Buffer at -20°C and all other reagents undiluted at 4°C for no more than 3 months.
Number of Targets Detected
43
Usage
This product is furnished for LABORATORY RESEARCH USE ONLY. Not for diagnostic or therapeutic use.